Monday, May 6, 2019
Circuit Protection and Polyphase Motors Assignment
Circuit Protection and Polyphase Motors - Assignment ExampleThese techniques result in a steep sack voltage to control over current and voltage during a dent in operation. Types of ancestry snow Circuit Breakers The Air blast circuit breakers can be divide into the following three types (a). Axial Blast ABCB (b). Axial Blast ABCB with Side Moving Contact (c). cut across Blast ABCB Construction (a). Axial Blast ABCB The axial blast air ABCB consists of 2 traces one is dogged and the other is movable. The fixed connectedness has an glinting chamber with a spring loading mechanism, and a nozzle porta over which the movable contact rests under the normal closed condition. In case a fault arises, a high Figure 1.Axial Blast ABCB (Courtesywww.electrical4u.com) air pressure in the arcing chamber causes the spring to deform. This produces an import of lengthening and cooling of the air column in the chamber which pushes out the movable contact. As a result of these changes an a rc voltage is produced which is much higher than the system voltage. The disparity in voltage levels results in the quenching of the arc produced. (b). Axial Blast ABCB with side moving contact Figure 2. ... As a result, an arc is drawn between the fixed and movable contact, which is passed over to the arcing electrode. This causes the surge to be quenched. (c). Cross Blast ABCB Figure 3. Cross Blast ABCB (Courtesywww.electrical4u.com) The cross blast ABCB has a fixed blast pipe. The moving contacts movement is perpendicular to the direction of the air blast from the blast pipe. An exhaust chamber having arc splitters is fitted on the same alignment as the blast pipe. When the movable contact is detached from the fixed contact an arc is established. High pressure air coming from the blast pipe enters the exhaust chamber subsequently passing through the contact breaker, forcefully taking the arc into the exhaust chamber. This results in the quenching of the arc. 1. b. OIL-FILLED rac ing circuit BREAKER Working Principle The oil-filled circuit breaker is one of the oldest types of circuit breakers. It employs mineral oil as the insulating medium to quench the surging arc. The fixed as well as the movable contacts are immersed in oil as a result the arc forms a bubble in the oil. The energy of the arc is utilized to decompose the oil into hydrogen gas. As a result arc quenching is obtained. Types of oil color Circuit Breakers vegetable oil circuit breakers can be broadly classified into two categories (a). Bulk Oil Circuit Breaker (b). Minimum Oil Circuit Breaker (a). Bulk Oil Circuit Breaker Construction Figure 4. Conceptual view of the Bulk Oil Circuit Breaker. (Courtesywww.electrical4u.com) The mint oil circuit breakers employ transformer insulating oil as the insulating and arc quenching medium. The current carrying contacts (fixed and movable) and the earthed separate of the circuit breaker are placed in a large quantity of oil in a closed tank or vessel. The oil
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.